Enforcement of motor vehicle laws, including parking privileges, is a local matter. Security barriers, including but not limited to, security bollards and security check points, shall not obstruct a required accessible route or accessible means of egress. Where provided, areas that are raised or depressed and accessed by ramps or platform lifts with entry ramps shall provide unobstructed turning space complying with 304. Swinging door and gate surfaces within 10 inches (255 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door or gate. Doors, doorways, and gates that are part of an accessible route shall comply with 404. At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing. 502.5 Vertical Clearance. EXCEPTION: A parallel approach complying with 305 shall be permitted at units for childrens use where the spout is 30 inches (760 mm) maximum above the finish floor or ground and is 3 1/2 inches (90 mm) maximum from the front edge of the unit, including bumpers. (3) For the purposes of this part, the term path of travel also includes the restrooms, telephones, and drinking fountains serving the altered area. If alterations to a qualified historic building or facility to achieve program accessibility would threaten or destroy the historic significance of the building or facility, fundamentally alter the program, or result in undue financial or administrative burdens, the Department of Justice ADA regulations allow alternative methods to be used to achieve program accessibility. Advertisements and other similar information shall not be required to be audible unless they convey information that can be used in the transaction being conducted. Emergency controls, including the emergency alarm, shall be grouped at the bottom of the panel. 206.2.16 Miniature Golf Facilities. The bottoms of handrail gripping surfaces shall not be obstructed for more than 20 percent of their length. This document contains scoping and technical requirements for accessibility to sites, facilities, buildings, and elements by individuals with disabilities. 703.2.2 Case. Where assistive listening devices are installed, place signs complying with 703.7.2.4 to identify those facilities which are so equipped. Accessible routes located on playing surfaces of miniature golf holes shall be permitted to use the exceptions in 1007.2. 408.3.2.1 Power Operation. Reinforcement must be sufficient to permit the installation of rear and side wall grab bars that fully meet all accessibility requirements including, but not limited to, required length, installation height, and structural strength. The clear width of accessible routes shall be permitted to be 36 inches (915 mm) minimum for a distance of 60 inches (1525 mm) maximum provided that multiple reduced width segments are separated by segments that are 60 inches (1525 mm) wide minimum and 60 inches (1525 mm) long minimum. 231.4.2 Partitions. Unless a clear or correct key is provided, each operable part shall be able to be differentiated by sound or touch, without activation. 1009.4.5 Grab Bars. Clearance around a water closet shall comply with 604.3. In golf, the starting place for the hole to be played. Ride seats designed for transfer should involve only one transfer. (B) For the purposes of this section, the term path of travel also includes the restrooms, telephones, and drinking fountains serving the altered area. (2) The portion of the residence covered under paragraph (b)(1) of this section extends to those elements used to enter the commercial facility, including the homeowners front sidewalk, if any, the door or entryway, and hallways; and those portions of the residence, interior or exterior, available to or used by employees or visitors of the commercial facility, including restrooms. (ii) Newly constructed or altered facilities or elements covered by 36.401 or 36.402 that were constructed or altered before March 15, 2012 and that do not comply with the 1991 Standards shall, on or after March 15, 2012, be made accessible in accordance with the 2010 Standards. The provisions of Chapter 5 shall apply where required by Chapter 2 or where referenced by a requirement in this document. Designations and indicators of car controls shall comply with 407.4.7. Amusement rides shall provide at least one wheelchair space complying with 1002.4, or at least one amusement ride seat designed for transfer complying with 1002.5, or at least one transfer device complying with 1002.6. (ii) A terminal, depot, or other station used for specified public transportation, or an airport passenger terminal. EXCEPTION: If at least 50 percent of the elevated play components are connected by a ramp and at least 3 of the elevated play components connected by the ramp are different types of play components, the play area shall not be required to comply with 240.2.1.2. Accessible routes serving miniature golf facilities shall comply with Chapter 4 except as modified by 1007.2. EXCEPTION: Wheelchair spaces in team or player seating areas serving areas of sport activity shall not be required to comply with 221.2.3. Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable. Operable parts shall comply with 309. 405.7.3 Length. However, handrails are required to comply with 505 when they are provided on walking surfaces with running slopes less than 1:20 (see 403.6). Buttons shall be arranged with numbers in ascending order. Where a stand-alone slide is provided, an accessible route must connect the base of the stairs at the entry point to the exit point of the slide. 208.1 General. 233.3.5 Dispersion. The golf club reach range applies to all holes required to be accessible. A side-wall grab bar complying with 604.5.1 shall be provided and shall be located on the wall closest to the water closet. 233.2 Residential Dwelling Units Provided by Entities Subject to HUD Section 504 Regulations. Sound pressure levels (SPL), expressed in decibels, measure output sound volume. 1009.2.1 Pool Lift Location. 206.2.14 Fishing Piers and Platforms. The centerline of the water closet shall be 16 inches (405 mm) minimum to 18 inches (455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment specified in 604.8.2. Similarly, casement windows, when open, cannot encroach more than 4 inches (100 mm) into circulation paths above 27 inches (685 mm). Where multiple sports fields or courts are provided, an accessible route is required to each field or area of sport activity. 404.2.5 Thresholds. (1) If an area containing a primary function has been altered without providing an accessible path of travel to that area, and subsequent alterations of that area, or a different area on the same path of travel, are undertaken within three years of the original alteration, the total cost of alterations to the primary function areas on that path of travel during the preceding three-year period shall be considered in determining whether the cost of making that path of travel accessible is disproportionate. A clear floor or ground space complying with 305 shall be provided. For example, a TTY required for a bank can satisfy the requirements for a building. 307.1 General. Where differences occur between this document and the referenced standards, this document applies. Truncated domes in a detectable warning surface shall have a center-to-center spacing of 1.6 inches (41 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch (17 mm) minimum, measured between the most adjacent domes on a square grid. Generally, rooms in a cluster are within sight of, or adjacent to, one another. Handrails shall not be required on ramps located within ground level use zones. 904.5.2 Tray Slides. At least one grab bar on each transfer step and the transfer platform or a continuous grab bar serving each transfer step and the transfer platform shall be provided. The Department of Justice ADA regulations also allow public entities to use alternative methods when altering qualified historic buildings or facilities in the rare situations where the State Historic Preservation Officer determines that it is not feasible to provide physical access using the exceptions permitted in Section 202.5 without threatening or destroying the historic significance of the building or facility. See additional requirements at 28 CFR 35.151(h) and 28 CFR 36.406(g). EXCEPTION: In residential dwelling units, a lavatory complying with 606 shall be permitted on the rear wall 18 inches (455 mm) minimum from the water closet centerline where the clearance at the water closet is 66 inches (1675 mm) minimum measured perpendicular from the rear wall. Where the conditions in exception 3 are satisfied, existing facilities are only required to have one accessible boat slip with a pier clearance which runs the length of the slip. Changes in level of 1/4 inch (6.4 mm) high maximum shall be permitted to be vertical. Cleats and other boat securement devices shall not be required to comply with 309.3. 1008.2.6.2 Use Zones. The clear floor or ground space shall be centered on the appliance. Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1. 206.5.1 Entrances. Where comparable units have vanity counter tops, accessible units should also have vanity counter tops located as close as possible to the lavatory for convenient access to toiletries. Raised diving boards and diving platforms shall not be required to comply with these requirements or to be on an accessible route. Advisory 216.3 Directional and Informational Signs. 1009.3.3 Handrails. 502.3.3 Marking. Platform lifts shall comply with ASME A18.1 (1999 edition or 2003 edition) (incorporated by reference, see Referenced Standards in Chapter 1). Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device, or supporting structure. A clear floor space complying with 305 positioned for forward approach shall be provided. Housing at a place of education that is subject to this part shall comply with the provisions of the 2010 Standards applicable to transient lodging, including, but not limited to, the requirements for transient lodging guest rooms in sections 224 and 806, subject to the following exceptions. 306.2.2 Maximum Depth. Car designations shall be provided in both tactile characters and braille. On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat. These regulations adopted revised, enforceable accessibility standards called the 2010 ADA Standards for Accessible Design 2010 Standards or Standards. Function key surfaces shall have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised plus sign; Decrease Value key: raised minus sign. Where one grab bar is provided, clearance shall be 24 inches (610 mm) minimum on both sides of the grab bar. The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection and building fire alarm activation. 408.4.4 Leveling. 1008.4.4 Entry Points and Seats. Where possible, designers are encouraged to locate the ride seat no higher than 17 to 19 inches (430 to 485 mm) above the load and unload surface. The section consists of (ADA) Chapters 1 and 2 and Chapters 3 through 10, of the 2004 ADAAG (36 CFR part 1191, appendices B and D, adopted as part of both the Title II and Title III 2010 Standards). 804.5 Storage. That portion of a pier, main pier, finger pier, or float where a boat is moored for the purpose of berthing, embarking, or disembarking. Doors shall not swing into the clear floor space required by 903.2. Changes in level shall comply with 303. Thus, while individuals who use wheelchairs need not be provided with the best seats in the house, neither may they be relegated to the worst. Additionally, such signs can be used to provide wayfinding information that cannot be efficiently conveyed on Braille signs. All public telephones shall have volume controls complying with 704.3. The Access Board has published technical assistance on assistive listening devices and systems. Controls shall comply with 309.4. 811.3 Height. Grab bars with circular cross sections shall have an outside diameter of 1 1/4 inches (32 mm) minimum and 2 inches (51 mm) maximum. 219.3 Receivers. Ensure that hand-held shower spray units are capable of delivering water pressure substantially equivalent to fixed shower heads. Handrail extensions shall not be required. 1008.2.5.2 Elevated. If the telephone or device is in a closed compartment, the compartment door hardware shall comply with 309. Clear floor or ground space complying with 305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench. Where exceptions for alterations to qualified historic buildings or facilities are permitted by 202.5, no more than one accessible route from a site arrival point to an accessible entrance shall be required. A component of an element used to insert or withdraw objects, or to activate, deactivate, or adjust the element. The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses. 408.4 Elevator Cars. Floor or ground surfaces of a turning space shall comply with 302. 305.7.2 Parallel Approach. Characters and their background shall have a non-glare finish. Where greater distances are required for transfers, providing gripping surfaces, seat padding, and avoiding sharp objects in the path of transfer will facilitate the transfer. Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with 902. With the exception of transit facilities, which are covered by regulations issued by the Department of Transportation, there is no process for certifying that an alternative design provides equivalent facilitation. 704.2.3 Telephone Directories. Preferably, carpet pad should not be used because the soft padding increases roll resistance. Means of egress shall comply with section 1003.2.13 of the International Building Code (2000 edition and 2001 Supplement) or section 1007 of the International Building Code (2003 edition) (incorporated by reference, see Referenced Standards in Chapter 1). Where the accessible route serving a floating boarding pier or skid pier is located within a boat launch ramp, the portion of the accessible route located within the boat launch ramp shall not be required to comply with 405. Hall signals, including in-car signals, shall comply with 407.2.2. 903.7 Wet Locations. Aisles shall comply with 403. 605.2 Height and Depth. 238.3 Practice Putting Greens, Practice Teeing Grounds, and Teeing Stations at Driving Ranges. Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. A walking surface that has a running slope steeper than 1:20. Work area equipment does not include passenger elevators and other accessible means of vertical transportation. At least one bathroom that is provided as part of a guest room shall comply with 603. 407.4.3 Platform to Hoistway Clearance. D9120 What is CDT Code for root canal? 208.3 Location. Advisory 233.3.4.1 Alterations to Vacated Buildings. Transient Lodging. The signal-to-noise ratio for internally generated noise in assistive listening systems shall be 18 dB minimum. Visual contrast shall be either light-on-dark or dark-on-light. The top of bathtub seats shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor. Normal maintenance, reroofing, painting or wallpapering, or changes to mechanical and electrical systems are not alterations unless they affect the usability of the building or facility. 206.8 Security Barriers. Ramps on accessible routes shall comply with 405. What is code for a dental bridge? The pontic tooth is dental code D6242 for noble metal and D6245 for porcelain. Low-level platforms shall be 8 inches (205 mm) minimum above top of rail. Where facilities with residential dwelling units are provided by entities subject to regulations issued by the Department of Housing and Urban Development (HUD) under Section 504 of the Rehabilitation Act of 1973, as amended, such entities shall provide residential dwelling units with mobility features complying with 809.2 through 809.4 in a number required by the applicable HUD regulations. 810.6 Rail Station Signs. Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground space. 704.2.1.1 Parallel Approach. 703.5.9 Line Spacing. The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface. Additional options such as armrests, head rests, seat belts, and leg support will enhance accessibility and better accommodate people with a wide range of disabilities. Section 233.3.4.2 uses the terms substantially altered and altered. A substantial alteration to a kitchen or bathroom includes, but is not limited to, alterations that are changes to or rearrangements in the plan configuration, or replacement of cabinetry. 806.3 Guest Rooms with Communication Features. Advisory 810.6.2 Routes and Destinations. Where handrails are provided, accessible routes shall be 60 inches (1525 mm) wide minimum. (2) Facilities with more than 50 beds covered by this part that provide common use bathing facilities shall provide at least one roll-in shower with a seat that complies with the relevant provisions of section 608 of the 2010 Standards. Accessible. Where a directional sign is required, it should be located to minimize backtracking. Parking space identification signs shall include the International Symbol of Accessibility complying with 703.7.2.1. (A) When the cost of alterations necessary to make the path of travel to the altered area fully accessible is disproportionate to the cost of the overall alteration, the path of travel shall be made accessible to the extent that it can be made accessible without incurring disproportionate costs. Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the finish floor. TTYs in public buildings shall be provided in accordance with 217.4.2.1. 703.2.7 Character Spacing. 221.2.1.3 Other Boxes. Placement of accessible cells or rooms in shift areas may allow additional flexibility in meeting requirements for dispersion of accessible cells or rooms. A short ramp cutting through a curb or built up to it. Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of 1/2 inch (13 mm) maximum within 10 inches (255 mm) horizontally of the minimum landing area specified in 405.7. 703.5.2 Case. 407.3.3.3 Duration. 203.7 Detention and Correctional Facilities. 206.2.17.2 Soft Contained Play Structures. Directional signs complying with 703.5 that indicate the location of the nearest entrance complying with 404 shall be provided at entrances that do not comply with 404. Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities, particularly on floating piers. Detectable warnings shall consist of a surface of truncated domes and shall comply with 705. Where an amusement ride provides shoulder-to-shoulder seating, companion seats shall be shoulder-to-shoulder with the adjacent wheelchair space. The International Symbol of TTY shall comply with Figure 703.7.2.2. 806.3.1 Alarms. The call button that designates the up direction shall be located above the call button that designates the down direction. Kitchens and kitchenettes shall comply with 804. Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides. 804.3.1 Clear Floor or Ground Space. The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck. In detention and correctional facilities, where at least one pay telephone is provided in a secured area used only by detainees or inmates and security personnel, at least one TTY shall be provided in at least one secured area. At least one accessible means of entry shall be provided for wading pools.
Janet Broderick Kraft, Advantages And Disadvantages Of Sovereignty, Strega Liqueur Glasses, Articles A
Janet Broderick Kraft, Advantages And Disadvantages Of Sovereignty, Strega Liqueur Glasses, Articles A